40 CFR Table 3 to Subpart FFF of Part 62: Table 3 to Subpart FFF of Part 62—Municipal Waste Combustor Operating Requirements
Where this section sits in the code
- Title 40—Protection of Environment
- CHAPTER I—ENVIRONMENTAL PROTECTION AGENCY
- SUBCHAPTER C—AIR PROGRAMS
- PART 62—APPROVAL AND PROMULGATION OF STATE PLANS FOR DESIGNATED FACILITIES AND POLLUTANTS
- Subpart FFF—Federal Plan Requirements for Large Municipal Waste Combustors Constructed on or Before September 20, 1994
Municipal waste combustor technology Carbon monoxide emissions level (parts per million by volume) a Averaging time (hrs) b
Mass burn waterwall 100 4
Mass burn refractory 100 4
Mass burn rotary refractory 100 24
Mass burn rotary waterwall 250 24
Modular starved air 50 4
Modular excess air 50 4
Refuse-derived fuel stoker 200 24
Fluidized bed, mixed fuel (wood/refuse-derived fuel) 200 c 24
Bubbling fluidized bed combustor 100 4
Circulating fluidized bed combustor 100 4
Pulverized coal/refuse-derived fuel mixed fuel-fired combustor 150 4
Spreader stoker coal/refuse-derived fuel mixed fuel-fired combustor 200 24
a Measured at the combustor outlet in conjunction with a measurement of oxygen concentration, corrected to 7 percent oxygen, dry basis. Calculated as an arithmetic average.
b Averaging times are 4-hour or 24-hour block averages.
c 24-hour block average, geometric mean.
Collected 2026-08-27T02:26:04Z. Source file · JSON