43 CFR 3175.111: General sampling requirements.
Where this section sits in the code
- Title 43—Public Lands: Interior
- Subtitle B—Regulations Relating to Public Lands
- CHAPTER II—BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR
- SUBCHAPTER C—MINERALS MANAGEMENT (3000)
- PART 3170—ONSHORE OIL AND GAS PRODUCTION
- Subpart 3175—Measurement of Gas
(a) Samples must be taken by one of the following methods:
(1) Spot sampling under §§ 3175.113 through 3175.115;
(2) Flow-proportional composite sampling under § 3175.116; or
(3) On-line gas chromatograph under § 3175.117.
(b) At all times during the sampling process, the minimum temperature of all gas sampling components must be the lesser of:
(1) The flowing temperature of the gas measured at the time of sampling; or
(2) 30 °F above the calculated hydrocarbon dew point of the gas.