46 CFR 162.050-19: -19 Oil content meter and bilge alarm test rig.
Where this section sits in the code
- Title 46—Shipping
- CHAPTER I—COAST GUARD, DEPARTMENT OF HOMELAND SECURITY
- SUBCHAPTER Q—EQUIPMENT, CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL
- PART 162—ENGINEERING EQUIPMENT
- Subpart 162.050—Pollution Prevention Equipment
(a) This section contains requirements for test rigs used in approval testing of oil content meters and meter. A typical test rig is described in Figure 162.050-19. The mixture pipe shown in Figure 162.050-19 is the portion of test rig piping between the oil injection point and the meter or bilge alarm piping.
(b) Each sample point on a test rig must be of the type described in Figure 162.050-17(e) and must be in a vertical portion of the test rig piping.
(c) Each test rig must have a centrifugal pump that is designed to operate at 1,000 revolutions per minute or more.
(d) The mixture pipe on a test rig must have a uniform inside diameter.
FIGURE 162.050-19—MONITOR AND BILGE ALARM TEST RIG
Collected 2026-08-27T02:26:22Z. Source file · JSON