(a) The longitudinal joint factor to be used in the design formula in § 192.105 is determined in accordance with the table 1 to this paragraph (a):

Table 1 to Paragraph (a)

Specification Pipe class Longitudinal joint factor (E)

ASTM A53/A53M (incorporated by reference, see § 192.7) Seamless 1.00

Electric resistance welded 1.00

Furnace butt welded .60

ASTM A106/A106M (incorporated by reference, see § 192.7) Seamless 1.00

ASTM A333/A333M (incorporated by reference, see § 192.7) Seamless 1.00

Electric resistance welded 1.00

ASTM A381 (incorporated by reference, see § 192.7) Double submerged arc welded 1.00

ASTM A671/A671M (incorporated by reference, see § 192.7) Electric-fusion-welded 1.00

ASTM A672/A672M (incorporated by reference, see § 192.7) Electric-fusion-welded 1.00

ASTM A691/A691M (incorporated by reference, see § 192.7) Electric-fusion-welded 1.00

API Spec 5L (incorporated by reference, see § 192.7) Seamless 1.00

Electric resistance welded 1.00

Electric flash welded 1.00

Submerged arc welded 1.00

Furnace butt welded .60

Other Pipe over 4 inches (102 millimeters) .80

Other Pipe 4 inches (102 millimeters) or less .60

(b) If the type of longitudinal joint cannot be determined, the joint factor to be used must not exceed that designated for “Other.”