49 CFR 192.115: Temperature derating factor (T) for steel pipe.

Read at publisher ↗
Where this section sits in the code
  1. Title 49—Transportation
  2. Subtitle B—Other Regulations Relating to Transportation
  3. CHAPTER I—PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION
  4. SUBCHAPTER D—PIPELINE SAFETY
  5. PART 192—TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS
  6. Subpart C—Pipe Design

The temperature derating factor to be used in the design formula in § 192.105 is determined as follows:

Gas temperature in degrees Fahrenheit (Celsius) Temperature derating factor (T)

250 °F (121 °C) or less 1.000

300 °F (149 °C) 0.967

350 °F (177 °C) 0.933

400 °F (204 °C) 0.900

450 °F (232 °C) 0.867

For intermediate gas temperatures, the derating factor is determined by interpolation.